HAI Energy Management Products
|
|
HAI's Omnistat-Z series
of thermostats have built-in Z-Wave™
transceivers. They will work with any
Z-Wave™ network. When connecting an
Omnistat-Z to an HAI controller, use the
Leviton Vizia RF to RS232 Serial Bridge (Leviton
part number RZCOP-1LW). |
| |
|
Omnistat Thermostats |
- Single stage heating and cooling
systems, non heat pump
- 1 stage heat, 1 stage cool
- Can be set to heat only or cool only
- Can power steal for retrofitting
heat/cool systems with only 4 wires
- Adjustable anticipator
- Use for forced air, radiant heat,
hydronic heat, steam, electric, gas,
oil, etc.
HAI's Thermostat
Isolation Module (HAI Part Number 29A00-1)
provides relay isolation for Omnistat RC-80B
thermostats. This optional module may be
needed for HVAC systems using non-standard
voltages.
HAI's Thermostat Power
Supply Module (HAI Part Number 30A00-1)
provides a power booster for Omnistat RC-80B
thermostats. This optional module may be
needed in retrofit applications where "HVAC
common" wire is not available. |
| |
| |
- Single stage heating and cooling
systems
- Zoned damper controls systems
- 1 stage cool, 1 stage heat with B
and O terminals for master control
|
| |
| |
- Two Stage heating and cooling
systems (Not heat pumps)
- 2 stage heat, 2 stage cool
- Energy Efficient Control of second
stage (EEC can be turned off if not
desired)
- Automatic anticipator
- Use for Forced Air systems with two
speed furnace, Two Speed air
conditioner, Two Stage furnace and/or
two stage air conditioner, electric,
gas, oil or other fuel.
|
| |
| |
- Single stage heat pumps with
auxiliary heating
- 2 stage heat, 1 stage cool
- Energy Efficient Control of
auxiliary heat to save energy (EEC can
be turned off if not desired)
- Automatic anticipator
- Use for water source heat pumps,
geothermal heat pumps or air to air heat
pumps with electric, hot water or other
source of auxiliary heat.
|
| |
| |
- Used for two speed (or two stage)
heat pumps with auxiliary heat
- 3 stage heat, 2 stage cool
- Energy Efficient Control of
auxiliary heating (EEC can be turned off
if not desired)
- Automatic anticipator
- Use for two speed heat pumps, two
stage heat pumps, WaterFurnace heat
pumps with Premier Control System
- Works with most variable speed units
|
| |
|
Omnistat Sensors &
Accessories |
|
Extended
Range Indoor/Outdoor
Temperature & Humidity Sensor |
|
The 31A00-8 Indoor/Outdoor Temperature
Sensor is used for sensing indoor or outdoor
temperature from -40 F to 120 F. It is
coated with a sealant to withstand outdoor
moisture and features a new, high accuracy
temperature sensor that doesn't need
calibration.
The temperature can be
used to activate programs for controlling
temperatures in attics, garages,
greenhouses, basements, wine cellars, and
coolers. The temperature can be displayed on
the console or spoken over the telephone. It
can also report, log, alert, or generate an
alarm if the temperature reaches freeze
conditions or if the temperature goes above
the high setpoint or drops below the low
setpoint programmed in the system.
The Model 31A00-8 also
includes a Humidity Sensor that is used for
reporting the outdoor or indoor relative
humidity from 0 to 100 percent. High and low
humidity limits can be set for taking action
(i.e. turning on the bathroom vent fan,
running a/c in de-humidification mode,
turning on humidifier in heating mode, etc.)
or reporting high or low humidity conditions
in homes, greenhouses, wine cellars,
coolers, humidors, etc. Controlling humidity
is particularly helpful in combating the
growth of mold in vulnerable areas of the
home, such as bathrooms, basements, attics,
etc.
This sensor cannot be
connected to a zone on an Expansion
Enclosure (i.e. Model 17A00) for
temperature. Run a 4-conductor wire from the
controller location to each Model 31A00-8.
For the Lumina, Lumina
Pro, Omni LT, Omni II, Omni IIe, or OmniPro
II home control systems. |
| |
| |
|
Extended
Range Indoor/Outdoor
Temperature Sensor |
|
The Model 31A00-7 Indoor/Outdoor Temperature
Sensor is used for sensing indoor or outdoor
temperatures from -40 F to 120 F. It is
coated with a sealant to withstand outdoor
moisture and features a new, high accuracy
temperature sensor that doesn't need
calibration.
The temperature can be
used to activate programs for controlling
temperatures in attics, garages,
greenhouses, basements, wine cellars, and
coolers. The temperature can be displayed on
the console or spoken over the telephone. It
can also report, log, alert, or generate an
alarm if the temperature reaches freeze
conditions or if the temperature goes above
the high setpoint or drops below the low
setpoint programmed in the system.
This sensor cannot be
connected to a zone on an Expansion
Enclosure (i.e. Model 17A00) for
temperature. Run a 4-conductor wire from the
controller location to each Model 31A00-7.
For the Lumina, Lumina
Pro, Omni LT, Omni II, Omni IIe, or OmniPro
II home control systems. |
| |
| |
This temperature sensor is used to monitor
the temperature of pools, spas, aquatic
ponds, and greenhouses. The temperature
sensing device is potted in a stainless
steel probe. It is designed specifically to
monitor water temperature from the
return/source and then report that
information back to an HAI Omni Family
controller. Supplied with stainless steel
mounting screws and waterproof connectors.
For the Lumina, Lumina
Pro, Omni LT, Omni II, Omni IIe, or OmniPro
II home control systems. |
| |
| |
The PESM (Programmable Energy Saver Module)
is used to override existing thermostats for
set-back control. It also may be used for
sensing and controlling other temperatures,
such as attic fans, garage fans,
greenhouses, basements, wine coolers,
humidors, etc. It may also be used to
control spa heaters with remote temperature
sensor.
The PESM reports
temperatures to the home control system, and
has a low voltage relay and LED indicator
for control. The PESM doubles as a freeze
sensor, which can cause the controller to
dial out in the event of a furnace failure.
For the Lumina, Lumina
Pro, Omni LT, Omni II, Omni IIe, or OmniPro
II home control systems. |
| |
|
Surface Mount
Remote Indoor
Temperature Sensor |
|
The Surface Mount Remote Indoor Temperature
Sensor may be mounted in the conditioned
space and the thermostat can be mounted
remotely for protection from tampering or
for aesthetic reasons.
This sensor uses twisted
pair, shielded cable from the Omnistat
thermostat to its location.
- For distances up to 100 feet,
typical twisted pair, PVC-insulated,
shielded cable may be used.
- For distances from 100-150 feet,
twisted pair with polypropylene
insulated conductors, shielded must be
used.
- For distances from 150-250 feet,
twisted pair with foam-polyethylene
insulated conductors, shielded must be
used.
- Wire runs must not exceed 250 feet.
The Remote Sensor must be
mounted in the same location appropriate for
a thermostat for best performance (for
example, on an inside wall, free of draft
from vents, away from sunlight, windows,
etc.).
This small (2 W X 1.5 H X
I D inches) unit is mounted on the surface
of the wall.
This sensor will work
with any Omni family or Lumina family home
control system. |
| |
| |
|
Flush Mount
Remote Indoor
Temperature Sensor |
|
The Flush Mount Remote Indoor Temperature
Sensor may be mounted in the conditioned
space and the thermostat can be mounted
remotely for protection from tampering or
for aesthetic reasons.
This sensor uses twisted
pair, shielded cable from the Omnistat
thermostat to its location.
- For distances up to 100 feet,
typical twisted pair, PVC-insulated,
shielded cable may be used.
- For distances from 100-150 feet,
twisted pair with polypropylene
insulated conductors, shielded must be
used.
- For distances from 150-250 feet,
twisted pair with foam-polyethylene
insulated conductors, shielded must be
used.
- Wire runs must not exceed 250 feet.
The Remote Sensor must be
mounted in the same location appropriate for
a thermostat for best performance (for
example, on an inside wall, free of draft
from vents, away from sunlight, windows,
etc.).
This small unit (disc is
1.5 inches in diameter) can be flush mounted
in the drywall and painted over to become
almost invisible in a residential
installation.
This sensor will work
with any Omni family or Lumina family home
control system. |
| |
| |
|
Omnistat
RC-80B Relay Isolation Module |
|
Relay isolation for Omnistat RC-80B
thermostat. This optional module may be
needed for HVAC systems using non-standard
voltages.
This module will work
with any Omni family or Lumina family home
control system. |
| |
| |
|
Omnistat
RC-80B Power Booster Module |
|
Power booster for Omnistat RC-80B
thermostat. This optional module may be
needed in retrofit applications where "HVAC
common" wire is not available.
This module will work
with any Omni family or Lumina family home
control system. |
| |
|
|
|
|