Hometek starts The Sails installation, a prestigious development situated at The Point.

>> More info


     
HAI Automation Simplified Since 1985

 

HAI Energy Management Products

 

HAI's Omnistat-Z series of thermostats have built-in Z-Wave™ transceivers. They will work with any Z-Wave™ network. When connecting an Omnistat-Z to an HAI controller, use the Leviton Vizia RF to RS232 Serial Bridge (Leviton part number RZCOP-1LW).

 

Omnistat Thermostats

Omnistat Single Stage Heat/Cool Thermostat

HAI Part Number: RC-80B
Omnistat-Z Model: RC-80BZ
 


 

RC80B Omnistat

  • Single stage heating and cooling systems, non heat pump
  • 1 stage heat, 1 stage cool
  • Can be set to heat only or cool only
  • Can power steal for retrofitting heat/cool systems with only 4 wires
  • Adjustable anticipator
  • Use for forced air, radiant heat, hydronic heat, steam, electric, gas, oil, etc.

HAI's Thermostat Isolation Module (HAI Part Number 29A00-1) provides relay isolation for Omnistat RC-80B thermostats. This optional module may be needed for HVAC systems using non-standard voltages.

HAI's Thermostat Power Supply Module (HAI Part Number 30A00-1) provides a power booster for Omnistat RC-80B thermostats. This optional module may be needed in retrofit applications where "HVAC common" wire is not available.

 
 

Omnistat Single Stage Heat/Cool for Zoned Systems Thermostat

HAI Part Number: RC-90B
Omnistat-Z Model: RC-90BZ
 


 

RC90B Omnistat

  • Single stage heating and cooling systems
  • Zoned damper controls systems
  • 1 stage cool, 1 stage heat with B and O terminals for master control
 
 

Omnistat Two Stage Heat/Cool Thermostat

HAI Part Number: RC-122B
Omnistat-Z Model: RC-122BZ
 


 

RC122B Omnistat

  • Two Stage heating and cooling systems (Not heat pumps)
  • 2 stage heat, 2 stage cool
  • Energy Efficient Control of second stage (EEC can be turned off if not desired)
  • Automatic anticipator
  • Use for Forced Air systems with two speed furnace, Two Speed air conditioner, Two Stage furnace and/or two stage air conditioner, electric, gas, oil or other fuel.
 
 

Omnistat Heat Pump Thermostat

HAI Part Number: RC-100B
Omnistat-Z Model: RC-100BZ
 


 

RC100B Omnistat

  • Single stage heat pumps with auxiliary heating
  • 2 stage heat, 1 stage cool
  • Energy Efficient Control of auxiliary heat to save energy (EEC can be turned off if not desired)
  • Automatic anticipator
  • Use for water source heat pumps, geothermal heat pumps or air to air heat pumps with electric, hot water or other source of auxiliary heat.
 
 

Omnistat Two Speed Heat Pump Thermostat


 


 

RC112B Omnistat

  • Used for two speed (or two stage) heat pumps with auxiliary heat
  • 3 stage heat, 2 stage cool
  • Energy Efficient Control of auxiliary heating (EEC can be turned off if not desired)
  • Automatic anticipator
  • Use for two speed heat pumps, two stage heat pumps, WaterFurnace heat pumps with Premier Control System
  • Works with most variable speed units
 

Omnistat Sensors & Accessories

Extended Range Indoor/Outdoor
Temperature & Humidity Sensor


 


 

31A00-8 Indoor / Outdoor Temp Sensor The 31A00-8 Indoor/Outdoor Temperature Sensor is used for sensing indoor or outdoor temperature from -40 F to 120 F. It is coated with a sealant to withstand outdoor moisture and features a new, high accuracy temperature sensor that doesn't need calibration.

The temperature can be used to activate programs for controlling temperatures in attics, garages, greenhouses, basements, wine cellars, and coolers. The temperature can be displayed on the console or spoken over the telephone. It can also report, log, alert, or generate an alarm if the temperature reaches freeze conditions or if the temperature goes above the high setpoint or drops below the low setpoint programmed in the system.

The Model 31A00-8 also includes a Humidity Sensor that is used for reporting the outdoor or indoor relative humidity from 0 to 100 percent. High and low humidity limits can be set for taking action (i.e. turning on the bathroom vent fan, running a/c in de-humidification mode, turning on humidifier in heating mode, etc.) or reporting high or low humidity conditions in homes, greenhouses, wine cellars, coolers, humidors, etc. Controlling humidity is particularly helpful in combating the growth of mold in vulnerable areas of the home, such as bathrooms, basements, attics, etc.

This sensor cannot be connected to a zone on an Expansion Enclosure (i.e. Model 17A00) for temperature. Run a 4-conductor wire from the controller location to each Model 31A00-8.

For the Lumina, Lumina Pro, Omni LT, Omni II, Omni IIe, or OmniPro II home control systems.

 
 

Extended Range Indoor/Outdoor
Temperature Sensor

 


 

31A00-7 Indoor / Outdoor Temp Sensor The Model 31A00-7 Indoor/Outdoor Temperature Sensor is used for sensing indoor or outdoor temperatures from -40 F to 120 F. It is coated with a sealant to withstand outdoor moisture and features a new, high accuracy temperature sensor that doesn't need calibration.

The temperature can be used to activate programs for controlling temperatures in attics, garages, greenhouses, basements, wine cellars, and coolers. The temperature can be displayed on the console or spoken over the telephone. It can also report, log, alert, or generate an alarm if the temperature reaches freeze conditions or if the temperature goes above the high setpoint or drops below the low setpoint programmed in the system.

This sensor cannot be connected to a zone on an Expansion Enclosure (i.e. Model 17A00) for temperature. Run a 4-conductor wire from the controller location to each Model 31A00-7.

For the Lumina, Lumina Pro, Omni LT, Omni II, Omni IIe, or OmniPro II home control systems.

 
 

Water Temperature Sensor

 


 

14A00-8 Water Temperature Sensor This temperature sensor is used to monitor the temperature of pools, spas, aquatic ponds, and greenhouses. The temperature sensing device is potted in a stainless steel probe. It is designed specifically to monitor water temperature from the return/source and then report that information back to an HAI Omni Family controller. Supplied with stainless steel mounting screws and waterproof connectors.

For the Lumina, Lumina Pro, Omni LT, Omni II, Omni IIe, or OmniPro II home control systems.

 
 

PESM

 


 

1101A PESM The PESM (Programmable Energy Saver Module) is used to override existing thermostats for set-back control. It also may be used for sensing and controlling other temperatures, such as attic fans, garage fans, greenhouses, basements, wine coolers, humidors, etc. It may also be used to control spa heaters with remote temperature sensor.

The PESM reports temperatures to the home control system, and has a low voltage relay and LED indicator for control. The PESM doubles as a freeze sensor, which can cause the controller to dial out in the event of a furnace failure.

For the Lumina, Lumina Pro, Omni LT, Omni II, Omni IIe, or OmniPro II home control systems.

 

Surface Mount Remote Indoor
Temperature Sensor

 


 

Model 23A00-1 Sensor The Surface Mount Remote Indoor Temperature Sensor may be mounted in the conditioned space and the thermostat can be mounted remotely for protection from tampering or for aesthetic reasons.

This sensor uses twisted pair, shielded cable from the Omnistat thermostat to its location.

  • For distances up to 100 feet, typical twisted pair, PVC-insulated, shielded cable may be used.

     
  • For distances from 100-150 feet, twisted pair with polypropylene insulated conductors, shielded must be used.

     
  • For distances from 150-250 feet, twisted pair with foam-polyethylene insulated conductors, shielded must be used.

     
  • Wire runs must not exceed 250 feet.

     

The Remote Sensor must be mounted in the same location appropriate for a thermostat for best performance (for example, on an inside wall, free of draft from vents, away from sunlight, windows, etc.).

This small (2 W X 1.5 H X I D inches) unit is mounted on the surface of the wall.

This sensor will work with any Omni family or Lumina family home control system.

 
 

Flush Mount Remote Indoor
Temperature Sensor

 


 

Model 23A00-2 Sensor The Flush Mount Remote Indoor Temperature Sensor may be mounted in the conditioned space and the thermostat can be mounted remotely for protection from tampering or for aesthetic reasons.

This sensor uses twisted pair, shielded cable from the Omnistat thermostat to its location.

  • For distances up to 100 feet, typical twisted pair, PVC-insulated, shielded cable may be used.

     
  • For distances from 100-150 feet, twisted pair with polypropylene insulated conductors, shielded must be used.

     
  • For distances from 150-250 feet, twisted pair with foam-polyethylene insulated conductors, shielded must be used.

     
  • Wire runs must not exceed 250 feet.

     

The Remote Sensor must be mounted in the same location appropriate for a thermostat for best performance (for example, on an inside wall, free of draft from vents, away from sunlight, windows, etc.).

This small unit (disc is 1.5 inches in diameter) can be flush mounted in the drywall and painted over to become almost invisible in a residential installation.

This sensor will work with any Omni family or Lumina family home control system.

 
 

Omnistat RC-80B Relay Isolation Module

 


 

29A00-1 Relay isolation for Omnistat RC-80B thermostat. This optional module may be needed for HVAC systems using non-standard voltages.

This module will work with any Omni family or Lumina family home control system.

 
 

Omnistat RC-80B Power Booster Module

 


 

30A00-1 Power booster for Omnistat RC-80B thermostat. This optional module may be needed in retrofit applications where "HVAC common" wire is not available.

This module will work with any Omni family or Lumina family home control system.

 

 

   © Copyright 2007. hometek.co.za Design by Hometek